Specification Lots 1,2,3
| Lot | Position | Item description | Unnamed: 3 | Quantity [pcs.] | Remarks The comparative specification should indicate any deviation from the technical parameters or functional description of the tender documents. If there is no deviation from the technical specification in columns B-E, please indicate "Yes". Otherwise, describe your special features in this column. | Unit cost, EUR | Unnamed: 7 | Control Panel Unit cost, EUR | Unnamed: 9 | Unnamed: 10 |
|---|---|---|---|---|---|---|---|---|---|---|
| all lots | General requirement | Availability of an authorized service center in Ukraine. In the event of a warranty case, the center must resolve the issue within 60 days from the date of application. | ||||||||
| 1 | 1.1 | Flanged gate valve, DN400 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN10 For potable water, raw water and treated wastewater Application:Potable water, raw water and treated wastewater/effluent with low content of suspended solids and fibrous impurities. Pressure rating:PN10. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN10 service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for the specified operating medium. Elastomer shall be suitable for potable-water applications where applicable. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for the specified pressure, temperature and operating medium. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN10. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Seat tightness:The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for the specified water/wastewater service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at the specified operating pressure and the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:The valve shall be supplied complete and suitable for installation in accordance with the manufacturer's standard installation requirements. Potable-water compliance:Where used in potable-water systems, all materials, elastomers and coatings in contact with drinking water shall comply with applicable national/EU requirements. Recognized drinking-water approval or equivalent conformity may be provided. | 70.0 | 2800.0 | |||||
| 1.2 | Flanged gate valve, DN500 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN10 For potable water, raw water and treated wastewater Application:Potable water, raw water and treated wastewater/effluent with low content of suspended solids and fibrous impurities. Pressure rating:PN10. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN10 service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for the specified operating medium. Elastomer shall be suitable for potable-water applications where applicable. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for the specified pressure, temperature and operating medium. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN10. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Seat tightness:The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for the specified water/wastewater service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at the specified operating pressure and the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:The valve shall be supplied complete and suitable for installation in accordance with the manufacturer's standard installation requirements. Potable-water compliance:Where used in potable-water systems, all materials, elastomers and coatings in contact with drinking water shall comply with applicable national/EU requirements. Recognized drinking-water approval or equivalent conformity may be provided. | 16.0 | 4300.0 | ||||||
| 1.3 | Flanged gate valve, DN600 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN10 For potable water, raw water and treated wastewater Application:Potable water, raw water and treated wastewater/effluent with low content of suspended solids and fibrous impurities. Pressure rating:PN10. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN10 service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for the specified operating medium. Elastomer shall be suitable for potable-water applications where applicable. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for the specified pressure, temperature and operating medium. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN10. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Seat tightness:The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for the specified water/wastewater service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at the specified operating pressure and the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:The valve shall be supplied complete and suitable for installation in accordance with the manufacturer's standard installation requirements. Potable-water compliance:Where used in potable-water systems, all materials, elastomers and coatings in contact with drinking water shall comply with applicable national/EU requirements. Recognized drinking-water approval or equivalent conformity may be provided. | 90.0 | 6500.0 | ||||||
| 1.4 | Flanged gate valve, DN400 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN16 For potable water supply systems Application:Potable water supply and distribution systems. Pressure rating:PN16. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN16 potable-water service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for potable water. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for PN16 potable-water service. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN16. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Testing:Production testing according to EN 12266-1 or equivalent recognized standard. The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for potable-water service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at PN16 and at the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:Suitable for installation in valve chambers Potable-water compliance:All wetted materials, elastomers and coatings shall comply with applicable requirements for potable-water contact. Recognized drinking-water approval/certification such as WRAS, ACS, DVGW, KIWA, SVGW, Belgaqua or equivalent nationally/internationally recognized conformity shall be accepted. | 8.0 | 2700.0 | ||||||
| 1.5 | Flanged gate valve, DN500 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN16 For potable water supply systems Application:Potable water supply and distribution systems. Pressure rating:PN16. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN16 potable-water service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for potable water. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for PN16 potable-water service. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN16. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Testing:Production testing according to EN 12266-1 or equivalent recognized standard. The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for potable-water service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at PN16 and at the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:Suitable for installation in valve chambers Potable-water compliance:All wetted materials, elastomers and coatings shall comply with applicable requirements for potable-water contact. Recognized drinking-water approval/certification such as WRAS, ACS, DVGW, KIWA, SVGW, Belgaqua or equivalent nationally/internationally recognized conformity shall be accepted. | 6.0 | 4300.0 | ||||||
| 1.6 | Flanged gate valve, DN600 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN16 For potable water supply systems Application:Potable water supply and distribution systems. Pressure rating:PN16. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN16 potable-water service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for potable water. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for PN16 potable-water service. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN16. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Testing:Production testing according to EN 12266-1 or equivalent recognized standard. The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for potable-water service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at PN16 and at the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:Suitable for installation in valve chambers Potable-water compliance:All wetted materials, elastomers and coatings shall comply with applicable requirements for potable-water contact. Recognized drinking-water approval/certification such as WRAS, ACS, DVGW, KIWA, SVGW, Belgaqua or equivalent nationally/internationally recognized conformity shall be accepted. | 17.0 | 6600.0 | ||||||
| 2 | 2.1 | Sewage pump Q= 250 m³/h, H=30-40m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip). | 20.0 | 15000.0 | Frequency converter 45 - 50 kW | 3900.0 | |||
| 2.2 | Sewage pump Q= 250 m³/h, H=50-60m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [75-80] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 14.0 | 22000.0 | Frequency converter 75 - 80 kW | 5800.0 | ||||
| 2.3 | Sewage pump Q= 250 m³/h, H=90-100m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [130-132] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 2.0 | 45000.0 | Frequency converter 130 -132 kW | 9000.0 | ||||
| 2.4 | Sewage pump Q= 500 m³/h, H=30-40m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [130-132] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 18.0 | 25000.0 | Frequency converter 90 -110 kW | 6100.0 | ||||
| 2.5 | Sewage pump Q= 500 m³/h, H=70-80m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [130-132] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 4.0 | 40000.0 | Frequency converter 160 -180 kW | 18500.0 | ||||
| 3 | 3.1 | Water supply pump, Q = 250 m³/h, H = 30–50 m | Application: Pumping of clean, treated or raw water in municipal water supply systems Pump type: Horizontal centrifugal pump for dry installation, long-coupled, suitable for continuous-duty water supply applications Operating range: The pump shall be suitable for variable-speed operation by means of a frequency converter Pump casing: Cast iron or ductile iron suitable for water service, or equivalent material with documented mechanical and corrosion resistance Impeller:Must be made of Ductile Iron EN-GJS-400-15 (EN 1563) or Stainless Steel EN 1.4301 (ISO 15510), or equivalent, strictly suitable for the pumped water properties. The impeller must be dynamically balanced in accordance with ISO 21940-11 (balance quality grade G2.5 or better. Shaft: High-strength stainless steel EN 1.4021 or EN 1.4401 (ISO 15510), or equivalent, corrosion-resistant Mechanical seal : The pump must be equipped with a balanced mechanical seal in accordance with EN 12756, featuring SiC/Carbon (or SiC/SiC) faces, EPDM elastomers, and AISI 316 stainless steel metal parts, or equivalent Bearings: Heavy-duty rolling bearings suitable for continuous 24/7 operation. The minimum calculated bearing operating life (L10h) must be at least 25,000 hours under maximum dynamic loads in accordance with ISO 281. Coupling: Torsionally flexible coupling with a spacer element (Spacer Coupling) to allow the "Back Pull-Out" maintenance method without dismantling the motor or piping, or equivalent. Equipped with a robust coupling guard according to EN ISO 13857. Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 10.0 | 8000.0 | Frequency converter 45 - 50 kW | 4000.0 | 0.0 | ||
| 3.2 | Water supply pump, Q = 250 m³/h, H = 50–75 m | Application: Pumping of clean, treated or raw water in municipal water supply systems Pump type: Horizontal centrifugal pump for dry installation, long-coupled, suitable for continuous-duty water supply applications Operating range: The pump shall be suitable for variable-speed operation by means of a frequency converter Pump casing: Cast iron or ductile iron suitable for water service, or equivalent material with documented mechanical and corrosion resistance Impeller:Must be made of Ductile Iron EN-GJS-400-15 (EN 1563) or Stainless Steel EN 1.4301 (ISO 15510), or equivalent, strictly suitable for the pumped water properties. The impeller must be dynamically balanced in accordance with ISO 21940-11 (balance quality grade G2.5 or better. Shaft: High-strength stainless steel EN 1.4021 or EN 1.4401 (ISO 15510), or equivalent, corrosion-resistant Mechanical seal : The pump must be equipped with a balanced mechanical seal in accordance with EN 12756, featuring SiC/Carbon (or SiC/SiC) faces, EPDM elastomers, and AISI 316 stainless steel metal parts, or equivalent Bearings: Heavy-duty rolling bearings suitable for continuous 24/7 operation. The minimum calculated bearing operating life (L10h) must be at least 25,000 hours under maximum dynamic loads in accordance with ISO 281. Coupling: Torsionally flexible coupling with a spacer element (Spacer Coupling) to allow the "Back Pull-Out" maintenance method without dismantling the motor or piping, or equivalent. Equipped with a robust coupling guard according to EN ISO 13857. Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 14.0 | 12000.0 | Frequency converter 75 - 80 kW | 5800.0 | ||||
| 3.3 | Water supply pump, Q = 250 m³/h, H =75-100 m | Application: Pumping of clean, treated or raw water in municipal water supply systems Pump type: Horizontal centrifugal pump for dry installation, long-coupled, suitable for continuous-duty water supply applications Operating range: The pump shall be suitable for variable-speed operation by means of a frequency converter Pump casing: Cast iron or ductile iron suitable for water service, or equivalent material with documented mechanical and corrosion resistance Impeller:Must be made of Ductile Iron EN-GJS-400-15 (EN 1563) or Stainless Steel EN 1.4301 (ISO 15510), or equivalent, strictly suitable for the pumped water properties. The impeller must be dynamically balanced in accordance with ISO 21940-11 (balance quality grade G2.5 or better. Shaft: High-strength stainless steel EN 1.4021 or EN 1.4401 (ISO 15510), or equivalent, corrosion-resistant Mechanical seal : The pump must be equipped with a balanced mechanical seal in accordance with EN 12756, featuring SiC/Carbon (or SiC/SiC) faces, EPDM elastomers, and AISI 316 stainless steel metal parts, or equivalent Bearings: Heavy-duty rolling bearings suitable for continuous 24/7 operation. The minimum calculated bearing operating life (L10h) must be at least 25,000 hours under maximum dynamic loads in accordance with ISO 281. Coupling: Torsionally flexible coupling with a spacer element (Spacer Coupling) to allow the "Back Pull-Out" maintenance method without dismantling the motor or piping, or equivalent. Equipped with a robust coupling guard according to EN ISO 13857. Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 10.0 | 20000.0 | Frequency converter 90 -110 kW | 6100.0 |
Scpecification Lots 4,5,6
| Lot | Position | Item description | Unnamed: 3 | Quantity [pcs.] | Remarks The comparative specification should indicate any deviation from the technical parameters or functional description of the tender documents. If there is no deviation from the technical specification in columns B-E, please indicate "Yes". Otherwise, describe your special features in this column. | Unit cost, EUR | Unnamed: 7 | Control Panel Unit cost, EUR | Unnamed: 9 | Unnamed: 10 |
|---|---|---|---|---|---|---|---|---|---|---|
| all lots | General requirement | Availability of an authorized service center in Ukraine. In the event of a warranty case, the center must resolve the issue within 60 days from the date of application. | ||||||||
| 4 | 4.1 | Flanged gate valve, DN400 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN10 For potable water, raw water and treated wastewater Application:Potable water, raw water and treated wastewater/effluent with low content of suspended solids and fibrous impurities. Pressure rating:PN10. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN10 service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for the specified operating medium. Elastomer shall be suitable for potable-water applications where applicable. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for the specified pressure, temperature and operating medium. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN10. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Seat tightness:The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for the specified water/wastewater service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at the specified operating pressure and the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:The valve shall be supplied complete and suitable for installation in accordance with the manufacturer's standard installation requirements. Potable-water compliance:Where used in potable-water systems, all materials, elastomers and coatings in contact with drinking water shall comply with applicable national/EU requirements. Recognized drinking-water approval or equivalent conformity may be provided. | 35.0 | 2800.0 | |||||
| 4.2 | Flanged gate valve, DN500 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN10 For potable water, raw water and treated wastewater Application:Potable water, raw water and treated wastewater/effluent with low content of suspended solids and fibrous impurities. Pressure rating:PN10. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN10 service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for the specified operating medium. Elastomer shall be suitable for potable-water applications where applicable. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for the specified pressure, temperature and operating medium. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN10. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Seat tightness:The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for the specified water/wastewater service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at the specified operating pressure and the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:The valve shall be supplied complete and suitable for installation in accordance with the manufacturer's standard installation requirements. Potable-water compliance:Where used in potable-water systems, all materials, elastomers and coatings in contact with drinking water shall comply with applicable national/EU requirements. Recognized drinking-water approval or equivalent conformity may be provided. | 8.0 | 4300.0 | ||||||
| 4.3 | Flanged gate valve, DN600 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN10 For potable water, raw water and treated wastewater Application:Potable water, raw water and treated wastewater/effluent with low content of suspended solids and fibrous impurities. Pressure rating:PN10. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN10 service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for the specified operating medium. Elastomer shall be suitable for potable-water applications where applicable. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for the specified pressure, temperature and operating medium. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN10. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Seat tightness:The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for the specified water/wastewater service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at the specified operating pressure and the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:The valve shall be supplied complete and suitable for installation in accordance with the manufacturer's standard installation requirements. Potable-water compliance:Where used in potable-water systems, all materials, elastomers and coatings in contact with drinking water shall comply with applicable national/EU requirements. Recognized drinking-water approval or equivalent conformity may be provided. | 45.0 | 6500.0 | ||||||
| 1.4 | Flanged gate valve, DN400 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN16 For potable water supply systems Application:Potable water supply and distribution systems. Pressure rating:PN16. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN16 potable-water service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for potable water. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for PN16 potable-water service. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN16. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Testing:Production testing according to EN 12266-1 or equivalent recognized standard. The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for potable-water service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at PN16 and at the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:Suitable for installation in valve chambers Potable-water compliance:All wetted materials, elastomers and coatings shall comply with applicable requirements for potable-water contact. Recognized drinking-water approval/certification such as WRAS, ACS, DVGW, KIWA, SVGW, Belgaqua or equivalent nationally/internationally recognized conformity shall be accepted. | 4.0 | 2700.0 | ||||||
| 4.5 | Flanged gate valve, DN500 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN16 For potable water supply systems Application:Potable water supply and distribution systems. Pressure rating:PN16. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN16 potable-water service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for potable water. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for PN16 potable-water service. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN16. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Testing:Production testing according to EN 12266-1 or equivalent recognized standard. The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for potable-water service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at PN16 and at the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:Suitable for installation in valve chambers Potable-water compliance:All wetted materials, elastomers and coatings shall comply with applicable requirements for potable-water contact. Recognized drinking-water approval/certification such as WRAS, ACS, DVGW, KIWA, SVGW, Belgaqua or equivalent nationally/internationally recognized conformity shall be accepted. | 2.0 | 4300.0 | ||||||
| 4.6 | Flanged gate valve, DN600 | FLANGED RESILIENT-SEATED WEDGE GATE VALVE – PN16 For potable water supply systems Application:Potable water supply and distribution systems. Pressure rating:PN16. Valve type:Flanged resilient-seated wedge gate valve for isolation service. Body and bonnet:Ductile iron or equivalent material suitable for PN16 potable-water service conditions. Wedge:Ductile iron wedge, fully encapsulated/vulcanized with EPDM or equivalent elastomer suitable for potable water. Stem:Non-rising stem made of stainless steel or equivalent corrosion-resistant material. Stem sealing:Reliable sealing system suitable for PN16 potable-water service. Bolting:Corrosion-resistant material suitable for the service conditions. Corrosion protection:Factory-applied fusion-bonded epoxy or equivalent heavy-duty corrosion-protection system suitable for buried and/or external installation. Coating shall comply with EN 14901-1 or an equivalent recognized standard. Flanged connection:Flanged ends according to EN 1092-2, PN16. Face-to-face dimensions:According to EN 558, Series 14 (F4). Design and performance:EN 1074-1 and EN 1074-2; EN 1171 where applicable. Testing:Production testing according to EN 12266-1 or equivalent recognized standard. The closed valve shall provide tight shut-off in accordance with the applicable requirements of EN 12266-1, with no visible leakage under the specified test conditions. Operating temperature:Suitable for potable-water service, approximately 0 °C to +70 °C. Operating conditions:The valve shall be capable of safe opening and closing at PN16 and at the maximum differential pressure declared by the manufacturer. Operating torque:The manufacturer shall declare the maximum operating torque and, where applicable, the torque required for gearbox or actuator selection. Actuation:Handwheel for manual operation as standard. The valve shall be suitable for installation of a gearbox or electric actuator where required. Installation:Suitable for installation in valve chambers Potable-water compliance:All wetted materials, elastomers and coatings shall comply with applicable requirements for potable-water contact. Recognized drinking-water approval/certification such as WRAS, ACS, DVGW, KIWA, SVGW, Belgaqua or equivalent nationally/internationally recognized conformity shall be accepted. | 10.0 | 6600.0 | ||||||
| 5 | 5.1 | Sewage pump Q= 250 m³/h, H=30-40m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip). | 10.0 | 15000.0 | Frequency converter 45 - 50 kW | 3900.0 | |||
| 5.2 | Sewage pump Q= 250 m³/h, H=50-60m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [75-80] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 6.0 | 22000.0 | Frequency converter 75 - 80 kW | 5800.0 | ||||
| 5.3 | Sewage pump Q= 250 m³/h, H=90-100m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [130-132] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 2.0 | 45000.0 | Frequency converter 130 -132 kW | 9000.0 | ||||
| 5.4 | Sewage pump Q= 500 m³/h, H=30-40m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [130-132] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 10.0 | 25000.0 | Frequency converter 90 -110 kW | 6100.0 | ||||
| 5.5 | Sewage pump Q= 500 m³/h, H=70-80m | Application: Municipal sewage pumping stations (KNS) for untreated or partially screened wastewater containing faecal matter, suspended, fibrous solids, and abrasive sand/grit.2 Pump type: Horizontal centrifugal sewage pump for dry-pit/dry-well installation, mounted on a common steel or cast iron baseframe. Installation: Dry installation outside the pumped liquid. Back Pull-Out design or equivalent allowing rotating element maintenance without disconnecting the casing from pipework. Operating point: As specified in the Schedule of Requirements Pump design: Non-clog sewage pump suitable for reliable operation with municipal wastewater Impeller: Single-channel, multi-channel, or equivalent non-clog design with hydraulic efficiency minimum 78-80% at BEP. Dynamically balanced. Free passage: Minimum 80 mm (or minimum 100 mm for capacities up to 500 m³/h). Liquid temperature: Maximum liquid temperature: minimum +40 °C. Pump materials: Wear-resistant cast iron (minimum EN-GJS-400 or equivalent wear-resistant alloy). Grey cast iron configurations must include replaceable wear components. Wear Protection: Replaceable wear rings or wear plates on the casing and/or impeller side. Shaft: Stainless steel (minimum AISI 431 or manufacturer's equivalent grade protected by a shaft sleeve). Mechanical seal:Double mechanical shaft seal operating in an oil chamber. Seal face materials on the liquid side shall be Silicon Carbide (SiC/SiC) or Tungsten Carbide. Oil chamber equipped with a leakage sensor. Bearings: Heavy-duty grease or oil-lubricated bearings with minimum L10 bearing life of 50,000 hours. Motor type: Three-phase squirrel-cage induction motor. Electrical data: Rated voltage: 400 V ±10 %. Rated frequency: 50 Hz. Motor efficiency: IE3 minimum according to IEC 60034-30-1. Insulation class: Class F minimum. Degree of protection: IP55-IP57 according to IEC 60034-5. If an IP68 motor is offered, it must include an integrated cooling jacket for continuous dry-run operation. Duty:Continuous duty, S1. Pump efficiency: Supplier shall declare hydraulic efficiency at the duty point. The duty point shall lie within the manufacturer's preferred operating range (close to BEP). Performance curve: Manufacturer's official Q-H, power consumption, and efficiency curves shall be submitted. Standards: EN 809 or equivalent for pump safety; IEC 60034 series or equivalent for the motor. Hydraulic testing and tolerances according to ISO 9906 (Class 2B or Class 1B). Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [130-132] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 2.0 | 40000.0 | Frequency converter 160 -180 kW | 18500.0 | ||||
| 6 | 6.1 | Water supply pump, Q = 250 m³/h, H = 30–50 m | Application: Pumping of clean, treated or raw water in municipal water supply systems Pump type: Horizontal centrifugal pump for dry installation, long-coupled, suitable for continuous-duty water supply applications Operating range: The pump shall be suitable for variable-speed operation by means of a frequency converter Pump casing: Cast iron or ductile iron suitable for water service, or equivalent material with documented mechanical and corrosion resistance Impeller:Must be made of Ductile Iron EN-GJS-400-15 (EN 1563) or Stainless Steel EN 1.4301 (ISO 15510), or equivalent, strictly suitable for the pumped water properties. The impeller must be dynamically balanced in accordance with ISO 21940-11 (balance quality grade G2.5 or better. Shaft: High-strength stainless steel EN 1.4021 or EN 1.4401 (ISO 15510), or equivalent, corrosion-resistant Mechanical seal : The pump must be equipped with a balanced mechanical seal in accordance with EN 12756, featuring SiC/Carbon (or SiC/SiC) faces, EPDM elastomers, and AISI 316 stainless steel metal parts, or equivalent Bearings: Heavy-duty rolling bearings suitable for continuous 24/7 operation. The minimum calculated bearing operating life (L10h) must be at least 25,000 hours under maximum dynamic loads in accordance with ISO 281. Coupling: Torsionally flexible coupling with a spacer element (Spacer Coupling) to allow the "Back Pull-Out" maintenance method without dismantling the motor or piping, or equivalent. Equipped with a robust coupling guard according to EN ISO 13857. Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 4.0 | 8000.0 | Frequency converter 45 - 50 kW | 4000.0 | 0.0 | ||
| 6.2 | Water supply pump, Q = 250 m³/h, H = 50–75 m | Application: Pumping of clean, treated or raw water in municipal water supply systems Pump type: Horizontal centrifugal pump for dry installation, long-coupled, suitable for continuous-duty water supply applications Operating range: The pump shall be suitable for variable-speed operation by means of a frequency converter Pump casing: Cast iron or ductile iron suitable for water service, or equivalent material with documented mechanical and corrosion resistance Impeller:Must be made of Ductile Iron EN-GJS-400-15 (EN 1563) or Stainless Steel EN 1.4301 (ISO 15510), or equivalent, strictly suitable for the pumped water properties. The impeller must be dynamically balanced in accordance with ISO 21940-11 (balance quality grade G2.5 or better. Shaft: High-strength stainless steel EN 1.4021 or EN 1.4401 (ISO 15510), or equivalent, corrosion-resistant Mechanical seal : The pump must be equipped with a balanced mechanical seal in accordance with EN 12756, featuring SiC/Carbon (or SiC/SiC) faces, EPDM elastomers, and AISI 316 stainless steel metal parts, or equivalent Bearings: Heavy-duty rolling bearings suitable for continuous 24/7 operation. The minimum calculated bearing operating life (L10h) must be at least 25,000 hours under maximum dynamic loads in accordance with ISO 281. Coupling: Torsionally flexible coupling with a spacer element (Spacer Coupling) to allow the "Back Pull-Out" maintenance method without dismantling the motor or piping, or equivalent. Equipped with a robust coupling guard according to EN ISO 13857. Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 7.0 | 12000.0 | Frequency converter 75 - 80 kW | 5800.0 | ||||
| 6.3 | Water supply pump, Q = 250 m³/h, H =75-100 m | Application: Pumping of clean, treated or raw water in municipal water supply systems Pump type: Horizontal centrifugal pump for dry installation, long-coupled, suitable for continuous-duty water supply applications Operating range: The pump shall be suitable for variable-speed operation by means of a frequency converter Pump casing: Cast iron or ductile iron suitable for water service, or equivalent material with documented mechanical and corrosion resistance Impeller:Must be made of Ductile Iron EN-GJS-400-15 (EN 1563) or Stainless Steel EN 1.4301 (ISO 15510), or equivalent, strictly suitable for the pumped water properties. The impeller must be dynamically balanced in accordance with ISO 21940-11 (balance quality grade G2.5 or better. Shaft: High-strength stainless steel EN 1.4021 or EN 1.4401 (ISO 15510), or equivalent, corrosion-resistant Mechanical seal : The pump must be equipped with a balanced mechanical seal in accordance with EN 12756, featuring SiC/Carbon (or SiC/SiC) faces, EPDM elastomers, and AISI 316 stainless steel metal parts, or equivalent Bearings: Heavy-duty rolling bearings suitable for continuous 24/7 operation. The minimum calculated bearing operating life (L10h) must be at least 25,000 hours under maximum dynamic loads in accordance with ISO 281. Coupling: Torsionally flexible coupling with a spacer element (Spacer Coupling) to allow the "Back Pull-Out" maintenance method without dismantling the motor or piping, or equivalent. Equipped with a robust coupling guard according to EN ISO 13857. Pump Control Panel with Integrated VFD Enclosure: Powder-coated steel ≥1.5 mm, RAL 7035, IP54, IK10, indoor, floor-standing or wall-mounted, lockable door, bottom cable entry. Thermostat-controlled ventilation with replaceable filters, anti-condensation heater. Ambient −5…+40 °C, humidity ≤95% non-condensing, altitude ≤1000 m. VFD: Integrated individual VFD [45-50] kW, efficiency ≥95%, design life ≥30,000 h, conformally coated PCBs (class 3C2). Sizing: VFD power and current ≥ motor rated values. Current margin ≥10–15%, overload ≥110% for 60 s, with derating for temperature, altitude and switching frequency. Heat-loss and ventilation calculation to be provided. Supply: 3 ph, 380…480 V ±10%, 50 Hz, phase asymmetry ≤3%. Output frequency 0–500 Hz. EMC / Harmonics: Built-in EMC filter C3, built-in DC choke, THDi ≤48%. Motor cable / protection: <55 kW: shielded ≥150 m, unshielded ≥300 m without external filters. ≥55 kW: output dU/dt filter in the panel OR motor with isolated bearing. Power section & safety: Main isolator interlocked with the door, input MCCB/fuses, Type 2 SPD, supply monitoring relay (phase loss, sequence, under/overvoltage), door E-stop to STO (SIL2 / PL d), PE busbar, 360° shield clamps, ≥20% spare terminals, marked wires and terminals. Control: Vector control with auto-tuning, PID, sleep mode, pump preset Door-mounted graphical display, Local–Off–Remote selector, start/stop Fault log with time stamp RS485 Modbus RTU, USB Cascade control (pump alternation) Adjustable min/max frequency, skip frequencies, ramps Auto restart after power loss, auto fault reset kWh meter, running-hours counter Password protection, parameter backup I/O: DI/DO ≥3/2; AI/AO ≥2/1 (4–20 mA input for pressure/level); relay outputs ≥2 (Run/Fault, potential-free); motor PTC input; flood sensor input. Protections: Motor phase loss, short circuit, ground fault, motor and VFD overtemperature, over/undercurrent, over/undervoltage, dry running, pump-room flooding (alarm and trip)." | 5.0 | 20000.0 | Frequency converter 90 -110 kW | 6100.0 |
Dropdown menu
| Type of Equipment | Unnamed: 1 | Unnamed: 2 | Unnamed: 3 | Unnamed: 4 | Unnamed: 5 | please choose |
|---|---|---|---|---|---|---|
| Notebook | Yes | |||||
| PC | No | |||||
| Accesorities | (Mouse, Keyboard, Docking Station..) | |||||
| Office technic | Telephone,MFD, printer | |||||
| Network components | Router, switch, UPS | |||||
| Cartridge | Justification for non-neutral specification | |||||
| Licence, Software | please choose | |||||
| Monitor | Special manufacturing | |||||
| TV | Compatibility/Standartization in the Project/ Partner organisation | |||||
| Spare parts/ Aditional equipment/ accessories only by one Supplier | ||||||
| Maintenance | ||||||
| Category of good: | ||||||
| please choose | ||||||
| S01 Food, beverages, tobacco products | ||||||
| S02 Computer system | ||||||
| S03 Telecommunications device | ||||||
| S04 Standard Software rent (goods) | ||||||
| S05 Standard Software buy (goods) | ||||||
| S06 Plant Equipment, tool | ||||||
| S07 Construction technology | ||||||
| S08 Office product, facility and technic, papeterie | ||||||
| S09 Literature | ||||||
| S10 Hardware rent | ||||||
| S11 Energy, extraction product, secondary raw material, residue | ||||||
| S12 Electric engineering, automation, process control engineering | ||||||
| S13 Vehicle (complete vehicle) | ||||||
| S14 Home economics, Home technology | ||||||
| S15 Laboratory material, laboratory technology | ||||||
| S16 Installation (complete) | ||||||
| S17 Medical device | ||||||
| S18 Machine, apparatus | ||||||
| S19 Occupational safety, accident prevention | ||||||
| S20 Marketing | ||||||
| S21 Automotive engineering, vehicle component | ||||||
| S22 Human and veterinary drug, pesticide, active ingredient | ||||||
| S23 Clothing and textiles | ||||||
| S24 Body care, personal hygiene | ||||||
| S25 Sport, playing, leisure | ||||||
| S26 Interior furnishing (excl. Office furnishings) |